UES30LCP1-SPC - Guangdong Fleming Electronic Technology Co.,Ltd
MENU
UES30LCP1-SPC

lMedical &I.T.E.safety approvals

lTouch current:≤100μA

lEnergy efficiency level VI

l≤0.1W standby power

l5.0V-20.0Voutputs,up to 30W

lUp to 5,000m operating altitude

lSupportPD3.0,PPS,QC4.0,FCP,SCP fast charging protocol



Model UES30LCP1-SPC Power 30W
Current 0.01-3.00A Output 5V/9V/12V/15V/20V
Size 80.0(L) 30.0(W) 57.9(H)mm
Contact us
ModelNumberVoltage(*1)
(V)
Current
(A)
Rated
Power
Ripple &Noise
     (max)(*2)
Voltage
Tolerance
Line &Load
Regulation
Efficiency
(Average)
Start Up
Delay
UES30LCP1-SPC5.0
0.01-3.00
   15.00W
  400mVpk-pk
±5%
Line:±2%
Load:±5%
81.38%≤3s
9.0 0.01-3.00
27.00W  400mVpk-pk±5%86.62%≤3s
12.0 0.01-2.5030.00W  400mVpk-pk±5%86.95%≤3s
15.0 0.01-2.0030.00W  400mVpk-pk±5%86.95%≤3s
20.0 0.01-1.5030.00W  400mVpk-pk±5%86.95%≤3s
Environmental
General
Operating Temperature0℃ to 40℃ Dimensions80(L)x30(W)x57.9(H)mm
Storage Temperature-20℃ to 80℃ Weight100g
Operating  Humidity
Storage  Humidity
10%to    90%RH,non-condensing
5%to  95%RH
 MTBF>100,000hrs MIL-HDBK-217 at 25℃
Operating Altitude5,000m

Safety Approvals
Safety Agency /Mark  Medical(Meet)  ITE(Meet)
CB  IEC60601-1  IEC62368-1
UL
TüV  SUD/Mark
  ANSI/AAMIES60601-1  UL62368-1
  CAN/CSA  C22.2  NO.60601-1
  EN60601-1
  CAN/CSA C22.2 NO.62368-1
Tüv  SUD/GS
  EN62368-1
CE
  EN62368-1
CCC
  GB4943.1
FCC
  FCC PART15
EMC
Emission
Medical                                  ITE
IEC
ConductionIEC/EN60601-1-2,CISPR 11                EN55032,CISPR 32
RadiationIEC/EN60601-1-2,CISPR 11                EN55032,CISPR 32
Harmonic Currents
Voltage Flicker
EN61000-3-2,Class A
EN61000-3-3
 EN61000-3-2,Class A
EN61000-3-3
ImmunityIEC/EN60601-1-2                          En55024,CISPR 35
ESDIEC61000-4-2   ±15KV air,±8KV contact
Radiated ImmunityIEC61000-4-3    10V/m,3V/m 80MHz-2.7GMHz
EFT/BurstIEC61000-4-4   ±2KVon AC port,±1KVonsignal ports
SurgeIEC61000-4-5   ±4KV DM/CM
Conducted ImmunityIEC61000-4-6   3Vrms,6Vrms (0.15MHz-80MHz)
Others
Dielectric Withstand Voltage 4,242VDC input to output
Insulation Resistance       100M Ohms,500VDC input to output



We regard talents as the driving force for enterprise development and attach great importance to the selection, training, employment and retention of talents. We have also established a complete training mechanism to help each new member grow rapidly, including basic qutraining, professional skills training, job training and management quality training.

Fleming fully ensures the rapid growth of each member by creating a clear upward path and a platform space for displaying capabilities.We are always striding forward to realize the vision of "a first-class international brand enterprise with advanced management system, excellent teamand excellent corporate culture"!