| ModelNumber | Voltage(*1) (V) | Current (A) | Rated Power | Ripple &Noise (max)(*2) | Voltage Tolerance | Line &Load Regulation | Efficiency (Average) | Start Up Delay | |||||||||||
| UES30LCP1-SPC | 5.0 | 0.01-3.00 | 15.00W | 400mVpk-pk | ±5% | Line:±2% Load:±5% | 81.38% | ≤3s | |||||||||||
| 9.0 | 0.01-3.00 | 27.00W | 400mVpk-pk | ±5% | 86.62% | ≤3s | |||||||||||||
| 12.0 | 0.01-2.50 | 30.00W | 400mVpk-pk | ±5% | 86.95% | ≤3s | |||||||||||||
| 15.0 | 0.01-2.00 | 30.00W | 400mVpk-pk | ±5% | 86.95% | ≤3s | |||||||||||||
| 20.0 | 0.01-1.50 | 30.00W | 400mVpk-pk | ±5% | 86.95% | ≤3s | |||||||||||||
| Environmental | General | |||||||||||
| Operating Temperature | 0℃ to 40℃ | Dimensions | 80(L)x30(W)x57.9(H)mm | |||||||||
| Storage Temperature | -20℃ to 80℃ | Weight | 100g | |||||||||
| Operating Humidity Storage Humidity | 10%to 90%RH,non-condensing 5%to 95%RH | MTBF | >100,000hrs MIL-HDBK-217 at 25℃ | |||||||||
| Operating Altitude | 5,000m | |||||||||||
| Safety Approvals | ||||||||||||
| Safety Agency /Mark | Medical(Meet) | ITE(Meet) | ||||||||||
| CB | IEC60601-1 | IEC62368-1 | ||||||||||
| UL TüV SUD/Mark | ANSI/AAMIES60601-1 | UL62368-1 | ||||||||||
| CAN/CSA C22.2 NO.60601-1 EN60601-1 | CAN/CSA C22.2 NO.62368-1 | |||||||||||
| Tüv SUD/GS | EN62368-1 | |||||||||||
| CE | EN62368-1 | |||||||||||
| CCC | GB4943.1 | |||||||||||
| FCC | FCC PART15 | |||||||||||
| EMC | |||||||||||
| Emission | Medical ITE | IEC | |||||||||
| Conduction | IEC/EN60601-1-2,CISPR 11 EN55032,CISPR 32 | ||||||||||
| Radiation | IEC/EN60601-1-2,CISPR 11 EN55032,CISPR 32 | ||||||||||
| Harmonic Currents Voltage Flicker | EN61000-3-2,Class A EN61000-3-3 | EN61000-3-2,Class A EN61000-3-3 | |||||||||
| Immunity | IEC/EN60601-1-2 En55024,CISPR 35 | ||||||||||
| ESD | IEC61000-4-2 ±15KV air,±8KV contact | ||||||||||
| Radiated Immunity | IEC61000-4-3 10V/m,3V/m 80MHz-2.7GMHz | ||||||||||
| EFT/Burst | IEC61000-4-4 ±2KVon AC port,±1KVonsignal ports | ||||||||||
| Surge | IEC61000-4-5 ±4KV DM/CM | ||||||||||
| Conducted Immunity | IEC61000-4-6 3Vrms,6Vrms (0.15MHz-80MHz) | ||||||||||
| Others Dielectric Withstand Voltage 4,242VDC input to output Insulation Resistance 100M Ohms,500VDC input to output |


We regard talents as the driving force for enterprise development and attach great importance to the selection, training, employment and retention of talents. We have also established a complete training mechanism to help each new member grow rapidly,
including basic qutraining, professional skills training, job training and management quality training. Fleming fully ensures the rapid growth of each member by creating a clear upward path and a platform space for displaying capabilities.We are always striding forward to realize the vision of "a first-class international brand enterprise with advanced